Batteries Intermediate

Sizing Your Battery Bank

How to size a battery bank for off-grid or backup use, including depth-of-discharge considerations and lithium vs. lead-acid choices.

20 min read Basic electrical knowledge

Daily Energy Needs

Start with your daily kWh consumption. Multiply by 1.3 to account for inverter and wiring losses. This is how much energy your battery bank must hold (before depth-of-discharge limits).

Depth of Discharge

Lead-acid batteries should not be discharged past 50%. Lithium batteries can typically go to 80-100%. Divide your needed capacity by the allowable DoD to get the rated capacity.

Voltage Matters

Higher system voltages (24V/48V) use thinner wire and are more efficient for larger systems. Choose an inverter and MPPT charge controller that match your chosen bank voltage.

Quick Safety Tips
  • Always disconnect power before working on any component.
  • Panels generate voltage in sunlight — even unplugged.
  • Use proper-rated DC breakers and fuses.
  • Check local codes and permit requirements first.
  • Contact a licensed electrician for grid connections.